SKU: E800089

Model P8

Continuous in-line measurement for 8″ process pipelines

8″ Pipeline Sensor for Brix, Total Solids & Density Measurement

Continuous in-line concentration measurement directly in 8″ process pipelines. The sensor measures total solids content — including both dissolved and suspended components — delivering stable, real-time data under high-capacity flow conditions without bypass loops or sample extraction.

Designed for major industrial operations including large sugar mills, high-volume food & beverage facilities, industrial dairy plants, and chemical processing where robust measurement and coating resistance are essential for large-scale continuous production control.

Sugar Processing

  • Primary evaporator circulation loops
  • Main crystallizer circulation lines
  • High-capacity syrup mains
  • Large-scale liquor transfer pipelines

Food & Beverage

  • Major production line transfers
  • High-volume concentrate processing
  • Large-scale industrial blending
  • Primary product distribution lines

Dairy

  • Main milk reception and processing lines
  • High-capacity whey processing mains
  • Large-scale dairy ingredient transfer
  • Primary production distribution pipelines

Chemical & Industrial

  • Major process circulation loops
  • High-capacity reactor systems
  • Large-scale industrial transfer mains
  • Primary chemical distribution lines

  • Measurement range (Brix / solids): 
    0-95% Factory configured to specific TS or Density range by customer specification
  • Accuracy & repeatability:
    +/- 0.01 % concentration
  • Sensitivity:
    +/-0.001% concentration
  • Measuring resolution:
    0.01% concentration
  • Outputs:TS % & Temperature,
    4 – 20 mA, Active and Isolated. Max load 750 Ohm.
  • Process conditions:
    • Ph= 3-14
    • Temperature=0 – 140 C.
    • Pressure: recommended min 1.5 bar to avoid free air
  • Sensor body: Aisi 316L.
     

Flanged process fitting.

Inmec Model P8 sensor installed on a vertical process pipeline

Control the process where it flows — inline, in real time.

3-year warranty

A full, industry-leading warranty reflecting confidence in long-term performance.

Stable signal despite coating and buildup

Maintains a stable measurement signal even when product coating or buildup is part of normal operation

Wide Measurement Range

Accurate measurement from low concentrations to high-solids processes — one sensor covers your full production spectrum.

Our main crystallizer circulation line operates at very high flow rates and Brix levels. The 8″ sensor delivers stable measurement continuously, even with heavy coating and crystal buildup.

Operations Manager, Sugar Refinery (Brazil)

Find the Right Configuration for Your Process Pipeline

Share your process details and our engineers will recommend the right configuration.

FAQ

Model P8: frequently asked questions

Can’t find what you’re looking for? Share your process details above and our engineers will recommend the right configuration.

What is the Inmec Model P8?

The Model P8 is a digital microwave sensor for continuous Brix, total solids and density measurement in 8″ process pipelines. It measures the flowing product directly in the line, without bypass loops or sample extraction.

Where is the Model P8 used?

In sugar mills the Model P8 is used in primary evaporator circulation loops, main crystallizer circulation lines, high-capacity syrup mains and liquor transfer pipelines. It is also used in major food and beverage transfer and concentrate lines, main milk reception and whey processing mains, and chemical circulation loops and reactor systems.

Does the Model P8 measure suspended solids as well as dissolved solids?

Yes. The Model P8 measures total solids, both dissolved and suspended, across the flowing product. This suits opaque, viscous and coating-prone streams and slurries, where optical sensors that measure only dissolved solids at a prism surface struggle.

Does coating or buildup affect the Model P8 measurement?

No. The digital microwave measurement extends into the product volume, so the signal stays stable when coating or buildup on the sensor surface is part of normal operation.

Which Inmec pipeline sensor size should I choose?

Choose the model that matches the pipe size: the P2 fits 2″ (DN50), the P4 4″ (DN100), the P6 6″ (DN150), the P8 8″ (DN200) and the P10 10″ (DN250) industrial process pipelines, all with a flanged fitting. For sanitary lines of 1.5–3″ (DN40–DN80) with a Tri-Clamp connection, use the Model P-TC, and for tanks and vessels the Model IL. All use the same digital microwave measurement.

How is the Model P8 installed?

The Model P8 installs directly in a 8″ (DN200) pipeline with a flanged process fitting. The pipe must run full, and a process pressure of at least 1.5 bar is recommended to avoid free air at the sensor.

Does the Model P8 need a separate transmitter?

No. All signal processing takes place in the sensor itself. It provides 4–20 mA outputs for total solids and temperature, active and isolated, with a maximum load of 750 Ω, directly to the PLC or DCS.

What are the measurement range and accuracy of the Model P8?

The measurement range is 0–95 % Brix or total solids, factory configured to the customer’s specific total solids or density range. Accuracy and repeatability are ±0.01 % concentration, sensitivity is ±0.001 % and measuring resolution is 0.01 %.

What process conditions does the Model P8 handle?

The Model P8 operates at pH 3–14 and 0–140 °C, with an AISI 316L sensor body. A process pressure of at least 1.5 bar is recommended to avoid free air at the sensor.

What warranty does the Model P8 have?

The Model P8 comes with a 3-year warranty, reflecting its long-term stability in continuous industrial operation.